Section  Four—MECHANICAL INSTRUMENTATION           177

                PNEUMATIC      TEMPERATURE       INSTRUMENTS


                                   Local  Mounted


                                  MAN  HOURS EACH



                                                                   Mail Hours
                               Item
                                                                     Eacli
       TT  temperature transmitter, pneumatic,  Foxboro  Model:  12A,
       Thermal System:  Gas pressure, Class IIIB. Range: -100 to  +1,000°  F.
       Bulb: 316 SS, adjustable union with bendable  18" extension'%"
                                                     1
                                         3
       diameter, insertion  adjustable,  8-21". Bushing: 4" NPT. Tubing: A"
                                                    3
       vinyl-covered  flexible  SS protection  over SS capillary. Output Signal:
       3-15 psi. Mounting: Universal bracket for surface  or 2" pipe.  With air
       filter-regulator set and mounting bracket.                    7.6
       TT temperature transmitter, pneumatic non-indicating,  Foxboro
       Model: 44BT, Mounting: Bracket for surface or 2" pipe.  Connections:
       Bottom. Range: -100 to  +1,000° F. Thermal System: Class  IIIB,  gas
                                      1
       pressure. Bulb: 316 SS, plain bulb. Tubing: 5' A" OD, SS. Output Signal:
       3-15 psi.  With air filter-regulator set and mounting bracket.  7.6
       TTI temperature transmitter, pneumatic indicating,  Foxboro
       Model: 45P. Case: Rectangular. Range: -300 to  +600° F. Scale:  Eccentric
       6-1/8" length. Output Signal: 3-15  psi. Thermal System: Class  IIIB, gas
       pressure. Bulb: 316 SS, fixed union with 8" bendable  extension.
       Tubing: 5'-1/8" OD, SS. With air  filter-regulator  set  and mounting yoke.
       TS temperature recorder,  direct connected. Foxboro  Model: 40 PR.
       Case: Rectangular. Mounting: Yoke. Connection: Bottom. Pen: One,
       V-type. Chart Drive: Electric,  115 volts,  60 Hz, 24-hour. Thermal System:
       Class III, Gas Pressure.  Bulb: 316 SS, fixed union with 8" bendable
                                3
       extension.  Bushing: Plain, 316 SS, A NPT. Tubing: 5'!4" OD, 316 SS, with
       mounting yoke.                                                15.2
       TC temperature controller, pneumatic,  direct connected.
       Foxboro Model: 43AP-FA4. Control Function: Proportional plus reset.
       Prop. Band: 4-400%. Reset Time: 0.5-25 minutes. Thermal System:
       Class III,  gas pressure. Bulb: 316 SS, fixed union with 8" bendable
                                                 3
       extension. Tubing:  &'%" OD 316 SS. Bushing: Plain, 316 SS, A"  NPT.
       With air filter-regulator set and mounting yoke.              17.
     Above man hours include checking out of storage, calibrating, hauling to erection site, installing, including connect-
     ing capillary bulb to process, testing,  and final check.
     Man hours do not include installing air supply or air signal lines. See other piping accounts for these time frames,
     Man hours do not, include electrical installation for electrical hook-up required for chart driver  on the recorders.
     See Electiicnl Man  Hour Manual  for these time  frames.