436




























                             Fig. 10. Fracture surface of the failed chromium-plated sleeve (center).































                             Fig. 11. Fracture surface of the failed chromium-plated sleeve (I.D.).



          5.  Discussion

            The destructive  examination  of  the shaft has shown that the failure initiated  at the external
          surface (where the fracture is intergranular with big grains, up to - 600 pm in diameter), progressing
   448   449   450   451   452   453   454   455   456   457   458