Page 89 - Fluid Power Engineering
P. 89

64    Cha pte r  T h ree












































          FIGURE 3.2  Commonly used connectors and coupling elements.



          3.3 Hoses
               Hoses are used to interconnect elements that vibrate or move relative
               to each other. They insure the required flexibility and can operate at
               high pressures. The proper hose diameter is determined according to
               the maximum flow rate and the selected fluid speed.

                                          4 Q
                                      d =   max                      (3.2)
                                           π v


               where    d = Hose inner diameter, m
                                              3
                     Q   = Maximum flow rate, m /s
                       max
                        v = Fluid mean velocity, m/s
   84   85   86   87   88   89   90   91   92   93   94