Page 121 - Fluid mechanics, heat transfer, and mass transfer
P. 121

FLOW MEASUREMENT
            98
            TABLE 4.2  Summary of Plus and Minus Points of Different Types of Flow Meters
                                     Liquids
            Flow Meter Type   Low m       High m      Slurries  Gases     Turndown Ratio  Accuracy ( %)     Cost

            Head type
            Orifice            Yes      Limited        No        Yes           20:1           2–3           Low
            Venturi           Yes      Limited        Yes       Yes           20:1           2–3           High
            Rotometers        Yes      Limited        Limited   Yes           10:1           2–4           Low
            Target Meters     Yes      Limited        Limited   No            —              —             Medium
            Velocity type
            Magnetic          Yes      Yes            Yes       No            20:1           0.5–1         High
            Vortex            Yes      Limited        No        Yes           20:1           1             Medium
            Displacement
            Turbine           Yes      Limited        Limited   Yes           10:1           0.25–1        Medium
            Oval Gear         Yes      Yes (>10 cP)   No        No            25:1           0.1–0.5       Medium
            Mass flow type
            Coriolis          Yes      Yes            —         Yes           100:1          0.05–0.1      High
            Gas mass flow      —        —              —         Yes           50:1           1.5–2         Medium


                  minor inconvenience, since it needs to be cleaned up  . Name some best practices that aid in the selection of
                  after the measurement.                             flow measurements.
                 & Applications: Bubble meters are used in laboratory  & Measurement of mass flow in gases and steam.
                  and low-flow research applications. Their use in    & Elimination of impulse lines.
                  more industrial applications is extremely limited.
                                                                     & Minimization of permanent pressure loss.
                  Some of the applications for a bubble flow meter
                                                                     & Selection of in-line meters for small lines and inser-
                  include the following:
                                                                       tion meters for large lines to reduce the overall
                  ➢ Supercritical fluid extraction.
                                                                       installation cost of the flow meter.
                  ➢ Chromatography column, detector and carrier gas
                                                                     & Elimination of mechanical meters to reduce mainte-
                    measurement.
                                                                       nance costs. Moving parts in mechanical meters
                  ➢ Monitoring post-detector flow volumes in HPLC
                                                                       require regular maintenance.
                    systems.
                                                                   . What are the common flow measurement problems and
                  ➢ Calibration and flow verification for variable area
                                                                     possible solutions?
                    and electronic flow meters.
                                                                     & Table 4.3 gives a summary of flow measurement
                  ➢ Accurate flow measurement of gas mixtures with-
                                                                       problems.
                    out recalibration.
                  ➢ Accurate flow measurement of changing gas
                  ➢ concentrations.                              4.1.9  Weirs
                  ➢ Calibration of air sampling pumps.
                                                                   . What are weirs? Name different types of weirs and give
               . Give a brief summary of plus and minus points of    their applications?
                different types of flow meters.                       & A weir is a dam over which the liquid flows.
                 & Table 4.2 summarizes the plus and minus points of  & Weirs operate on the principle that an obstruction in a
                  different types of flow meters.                       channel will cause water to back up, creating a high

            TABLE 4.3  Summary of Flow Measurement Problems
            Symptom                      Problem Source                  Solution
            Low mass flow indicated       Liquid droplets in gas         Install demister upstream. Heat gas upstream of sensor.
            Mass flow error               Static pressure change in gas  Add pressure recording pen
            Transmitter zero shift       Free water in fluid             Mount transmitter above taps
            Measurement is high          Pulsation in flow               Add process pulsation dampener
            Measurement error            Nonstandard pipe runs          Estimate limits of error
   116   117   118   119   120   121   122   123   124   125   126