TABLE 1.2 Council of American Structural Engineers Calculation Review Checklist (Continued)


             Project:         Project Manager:        Reviewer:
             Project No.:     Engineer:               Date:



                           Item               Yes   No  N/A       Comment

               U. Are there any special requirements
                  for steel deck imposed by noncode
                  agencies such as Factory Mutual?
              IX. Steel Joist and Joist Girder Design
               A. Does span-to-depth ratio exceed
                  minimum for floor and roofs?
               B. Are loads noted for cantilever
                  ends?
               C. If joist and girders are part of lat-
                  eral load-resisting system, is
                  moment of inertia correct?
               D. Has adequate bearing been pro-
                  vided for ends of joist and girders?
               E.  Have connection details been
                  shown where both joists and beams
                  are to bear on tops of columns?
               F.  Are uplift forces noted for joist and
                  girders?
               G. Have joists been checked for
                  ponding?
               H. Has special equipment, such as bas-
                  ketball goals, folding partitions, and
                  mechanical units, been included in
                  design?
              X. Timber Design
               A. Are types and stress grades of lum-
                  ber adequately defined?
               B. Have unbraced lengths and slender-
                  ness been checked?
               C. Have criteria for fire-resistant con-
                  struction been met?
               D. Have deflections of members and
                  frames been considered in design?
               E.  Have repetition and duration loads
                  been considered in design?
               F.  Have nailing schedules been cal-
                  culated, or are code schedules
                  adequate?