TABLE 1.3 Council of American Structural Engineers Drawing Review Checklist (Continued)
Project: Project Manager: Reviewer:
Project No.: Engineer: Date:
Item Yes No N/A Comment
B. Verified property line dimensions
on site plan against architectural
drawings?
C. Verified column lines on structural
and architectural drawings?
D. Verified all column locations and
orientation are same on structural
and architectural drawings?
E. Verified perimeter slab on structural
matches architectural?
F. Verified all depressed or raised
areas of slabs are indicated?
G. Verified slab elevations?
H. Verified perimeter roof line and
slope with architectural roof plan?
I. Verified all expansion joint loca-
tions against architectural drawing?
J. Verified location of control joints in
walls?
K. Checked architectural drawings for
lintels that are required, particularly
in non-load-bearing walls?
L. Checked for folding suspended par-
titions and their support?
M. Designed stairs and landings and
coordinated with architect?
N. Coordinated elevator cells
1. Shelf angles
2. Divider beam
3. Max. spacing of guiderail supports
4. Hoist beam in penthouse
5. Elevator beams
O. Coordinated wall sections?
P. Verified that brick ledges are prop-
erly shown?