Page 176 - Formulas and Calculations for Petroleum Engineering
P. 176

Drilling engineering formulas and calculations Chapter  2  169




                D r :  Rod Diameter (in.)
                L S :  Stroke Length (in.)
                N C :  Number of Cylinders (unitless)
                n v :  Volumetric Efficiency (unitless)


             Output(s)

                V t :  Volume of Fluid Displaced (bbl/stroke)



             Formula(s)

                                                                  2     2
                                                    N   L     2   D L   D   n v
                                                      C
                                                                       r
                                                         S
                                                V ¼
                                                 t
                                                             42   294
             Reference: Samuel. E Robello. 501 Solved Problems and Calculations for Drilling Operations. Sigma Quadrant. 2015.
             Houston, Texas, Page: 49.
             2.228 Volume of fluid displaced for single-acting pump
             Input(s)

                D L :  Piston Diameter (in.)
                L S :  Stroke Length (in.)
                N C :  Number of Cylinders (unitless)


             Output(s)

                V t :  Volume of Fluid Displaced (bbl)


             Formula(s)

                                                              2
                                                          p   D   L   N C
                                                              L
                                                                 S
                                                      V ¼
                                                       t
                                                                4
             Reference: Samuel. E Robello. 501 Solved Problems and Calculations for Drilling Operations. Sigma Quadrant. 2015.
             Houston, Texas, Page: 47.


             2.229 Volume of fluid displaced for triplex pump
             Input(s)

                D L :  Piston Diameter (in.)
                L s :  Stroke Length (in.)
                n v :  Volumetric Efficiency (unitless)


             Output(s)

                V t :  Volume of Fluid Displaced (bbl/stroke)
   171   172   173   174   175   176   177   178   179   180   181