Be st Practice 6 .9           Gas Turbine Best Practices


        Table 6.9.1 Spreadsheet for trending gas turbine performancedCont'd
        What Action is Required Based on
        Gas Turbine Bearing info. Above?


        Air Filtration Sys. Condition
        Filter DP (bard)
        Action of Self Cleaning Air System
        (Active or Inactive)?
        Action?


        Variable Inlet Guide Vanes
        Hyd. Supply Differential
        Press. (bard)
        Guide Vane Position
        Air Flow Set Point
        Measured Air Flow
        IGV Exhaust Temp. Reference

        Measured Exhaust Temp. ( C)

        Action?


        Cooling and Sealing Air Sys.
        Cooling Air Pressure (bara)
        Other Cooling Sys. Observations
        Air Sealing System Supply
        Pressure (bara)


        Fuel Gas System
        Ambient Temp. ( C)                e          e          e          e         e          e

        Relative Humidity
        Fuel Supply Pressure (bara)

        Fuel Flow Rate (kg/hr)
        Fuel Pressure Upstream of
        Shut Off Valve (bara)
        Fuel Shut Off Valve Position
        Fuel Pressure Upstream of Fuel
        Control Valve (bara)
        Fuel Control Valve Position
        Fuel Supply Pressure to
        Combustors (bara)
        Action?