FIGURE 5.13   Comparison of two-pulse canceller frequency response with
               unstaggered waveform and 3:4 staggered waveform: (a) Two PRIs in a 3:4
               stagger ratio, (b) five PRIs in a 51:62:53:61:58 stagger ratio. The inset expands
               the portion of the graph near zero frequency.



                     It remains to determine the effect of the pulse stagger on the unambiguous
               range.  The  unambiguous  range R  of the staggered-PRI system is simply the
                                                       uas