                                               Table 2-30
                         Comparison of LPG Treater Operating Data with LLE Calculations

                  Case                  1                2                 3
                                 Plant            Plant             Plant
                                 Data   Calculated   Data   Calculated   Data   Calculated
                  Hydrocarbon
                    Rate, am      100     103      780      780      208      210
                    T,"F         50-60    55        90       90     77-89     83
                    P, psig      500      500      535      535      835      835
                  COz in, ppm    10,000   10,000   2,030    2,023   33,000   33,000
                  H2S in, ppm     -       -       Trace     2.7
                  CO, out, ppm    0      0.056     e100     0.42    Trace     0.4
                  H2S out. ppm    -       -        -        0.01     -        -
                  Amine          MEA     MEA       MEA     MEA      MEA      MEA
                    wt%           20      20        15       15      20       20
                    Flow, gal/min   10.8   10       34       34      54       50
                    Ideal Stages**   -     3       -         2       -         2
                    Lean Loading*   0.10   0.108   0.10     0.13     0.10     0.1 1
                    Rich Loading*   0.44   0.44    0.28     0.32     0.53     0.53
                  Contactor      three 124 sections of   two 124 sections of
                                     psckitlg          Packing         18 ft of packing
                  Packing Type      1-in. Intalox        -                 -
                       -
                         ..
                  Contactor. Diam., in.   30             -                 48
                  Case                  4                5                 6
                                 Plant            Plant             Plant
                                 Data   Calculated   Data   Calculated   Data   Calculated
                  Hydrocarbon
                    Rate, gpm    265      273      42       44       21       22
                    T,"F          -       80      80-90      85      -        85
                    P: psig      305      305      -        200      265      265
                  COz in, ppm    2,460   2,450     5,000    5,020    nil      -
                  H2S in. ppm    270      270      -        -        1,080   1,080
                  C02 out, ppm   Trace    1.2      100      47       -        -
                  H2S out, ppm    nil     5.9      -        -        nil      9.2
                  Amine          DEA      DEA     MEA      MEA      MEA      MEA
                    wt%.          20      20        a        8        5        5
                    Flow,gal/min.   20    20       5.3      5.3       5        5
                    Ideal Stages**   -     2       -         1       -         1
                    LeanLoading*   0.07   0.05     0.10     0.10     0.07     0.07
                    Rich Loading*   0.30   0.27    0.44     0.13     0.13     0.13
                  Contactor   two 8-ft sections of packing   10 perforated trays   jet eductor-mixer
                  Packing Type     1%"  ceramic
                  Contactor Diam.. in   66

                                                                 (table continued on nextpage)