Quality Control and Nondestructive Tests  191















































            Figure 5.4 Two methods of scanning with thermal NDT system. In (a) the
            focused thermal source and radiometer sensor are stationary while the
            product is moved in two directions to produce the scanning pattern. In (b)
            the product moves in one direction as the radiometer detector oscillates to
            provide the scanning motion. 6

              Through-put rate required of the NDT process
              Required documentation of the process and test results.


            5.4  Testing of Failed Joints for Cause
            of Failure

            Close examination of failed joints can sometimes lead to an explana-
            tion of why the specimen failed. With visual or microscopic examina-