                   Table 9.12. Land based installations. 600/1000 V. Cu/PVC/PVC/AWA/PVC single core

           Nominal     Air     Air     Ducts         Direct buried                Notes
           conductor  trefoil   3      trefoil
                  2
           area (mm )       horizontally     trefoil    3          3
                              spaced                horizontally  horizontally
                                                     touching   spaced
               50      193     247      193   203      193        202    Thermal resistivity of
                                                                                   ◦
               70      243     307      229   248      233        243      soil is 1.2 Cm/W
               95      298     372      269   297      277        288    Ambient air
                                                                                        ◦
              120      347     429      302   337      315        326      temperature is 30 C
              150      395     472      324   376      347        355    Depth of laying cables
              185      452     528      356   423      386        393      is 0.5 m
              240      532     606      398   485      441        443    Standard ground
                                                                                        ◦
              300      607     672      435   542      490        486      temperature is 15 C
              400      690     719      460   600      533        516    Conductor surface
                                                                                        ◦
                                                                           temperature is 70 C
                            ◦
           Ambient air temperature C  25  30      35     40      45      50     55      60
           Rating factor K air for cables  1.02  1.0  0.94  0.87  0.79   0.71    0.61    0.50
             laid in air

           Table 9.13. Land based installations. 600/1000 V. Cu/PVC/PVC/AWA/PVC single core Cu/PVC/PVC/SWA/
           PVC 3 and 4 cores

           Nominal conductor   Single cores in trefoil   3 and 4 cores      Approximate armouring
                  2
           area (mm )                                                            resistance
                             Resistance  Reactance  Resistance  Reactance    AWA         SWA
                                                                                            ◦
                                                         ◦
                                                                                ◦
                                  ◦
                              at 70 C    at50 Hz     at70 C     at50 Hz     at80 C      at 80 C
                              (ohm/km)   (ohm/km)   (ohm/km)    (ohm/km)   (ohms/km)   (ohms/km)
                  1.5                                14.451      0.104       2.39       11.40
                  2.5                                 8.868      0.101       1.99        9.48
                  4                                   5.518      0.099       1.16        5.52
                  6                                   3.688      0.094       1.03        4.92
                 10                                   2.186      0.090       0.857       4.08
                 16                                   1.380      0.087       0.554       2.64
                 25                                   0.870      0.084       0.529       2.52
                 35                                   0.627      0.081       0.479       2.28
                 50            0.464       0.112      0.464      0.081       0.328       1.56
                 70            0.321       0.107      0.321      0.079       0.302       1.44
                 95            0.232       0.103      0.232      0.077       0.247       1.176
                120            0.184       0.103      0.184      0.076       0.179       0.852
                150            0.150       0.101      0.150      0.076       0.164       0.780
                185            0.121       0.099      0.121      0.076       0.149       0.708
                240            0.0927      0.096      0.0929     0.075       0.131       0.624
                300            0.0751      0.094      0.0752     0.074       0.118       0.564
                400            0.0600      0.091      0.0604     0.074       0.0857      0.408