Design of Connections for Axial, Moment, and Shear Forces

                            Design of Connections for Axial, Moment, and Shear Forces  99

                         AISC 13th Manual (2005). The slip resistance per bolt can be cal-
                         culated as
                              R 5  mD h T 5 1.0s0.50ds1.13ds1.0ds51d 5 28.8 kips
                                n
                                        u sc b
                         The tensile strength per bolt, excluding prying, from Table 7-2 is
                         53.0 kips.
                                         5.5 2 0.75
                                     b              5 2.375
                                              2
                                         9 2 5.5
                                     a           5 1.75 , 1.25 3 2.375  ok
                                            2
                                     b   2.375   0.5   1.875
                                     a   1.75   0.5   2.25
                                         1.875
                                                 0.833
                                          2.25
                                             1.0625
                                           1          0.646
                                                3
                         Shear per bolt   V   250/14   17.9   28.8 kips, ok. Tension per
                         bolt   T   87/14 5 6.21 kips.  Thus
                                                   17.9
                             r    1.13   51   a1 2      b 5 21.8 kips . 6.21 kips, ok
                               n                   28.8
                             1
                         Try  / plate
                              2
                                           4.44 3 21.8 3 1.875
                                     t 5                      5 1.02
                                     c
                                         B       3 3 58
                                               1         1.02  2
                                     r 5               ca    b 2 1d 5 2.67
                                         0.646 3 1.833    0.5
                         Use      1

                                         0.5  2
                             T   21.8  a     b 3 1.833 5 9.60 kips . 6.21 kips  ok
                               d        1.02
                                 1
                         Use the  / -in plate for the end plate.
                                  2
                       c. Truss vertical flange: The flange thickness of the W14   61 is
                         0.645 in which exceeds the end plate thickness as well as being
                         Grade 50 steel. The truss vertical flange is therefore, ok by inspec-
                         tion, but a calculation will be performed to demonstrate how the
                         flange can be checked. A formula (Mann and Morris, 1979) for an
                         effective bolt pitch can be derived from yield-line analysis as

                                              psn 2 1d 1  b 1 2a
                                        p
                                          eff          n



                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.