Page 115 - Handbook of Structural Steel Connection Design and Details
P. 115
Design of Connections for Axial, Moment, and Shear Forces
100 Chapter Two
where the terms are as previously defined in Fig. 2.11. For the pre-
sent case
5.5 2 0.375
b 5 5 2.5625
2
10 2 5.5
a 5 5 2.25
2
n 7
p 3
3 3 s7 2 1d 1 3 2.5625 1 2 3 2.25
p 5 4.36
eff 7
Once p is determined, the prying action theory of the AISC
eff
Manual is applied.
b b 5 2.5625
b 2.5625 0.5 2.0625
a
a smaller of and a for the end plate 1.75 1.25 2.5625 ok
a 1.75 0.5 2.25
br
5 0.917
ar
1 1.0625/4.36 0.756
4.44 3 21.8 3 2.0625
t c 5 5 0.839 in
B 4.36 3 65
1 0.839 2
r 5 ca b 2 1d 5 0.477
0.756 3 1.917 0.645
0.645 2
T 21.8 a b 3 s1 1 0.477 3 0.756d
d 0.839
17.5 kips > 6.21 kips, ok
3. Truss vertical-to-top chord connection:
The forces on this connection, from Figs. 2.20 and 2.24 are
Vertical Q 298 920 cos (36.7) tan (17.7) 63 kips
Horizontal 87 kips
Converting these into normal and tangential components
T 87 cos 63 sin 64 kips
BC
N 87 sin 63 cos 86 kips (compression)
BC
Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
Any use is subject to the Terms of Use as given at the website.