Welded Joint Design and Production

                    192   Chapter Three






















                    Figure 3.8  Self-shielded FCAW. (Courtesy of The Lincoln
                    Electric Company.)





























                    Figure 3.9  Gas-shielded FCAW. (Courtesy of The Lincoln Electric
                    Company.)


                    supplied shielding gas. In many cases, CO is used, although other gas
                                                           2
                    mixtures may be used, for example, argon/CO mixtures. Both types of
                                                              2
                    flux-cored arc welding are capable of delivering weld deposits that meet
                    the quality and mechanical property requirements for most structure
                    applications. In general, the fabricator will utilize the process that offers
                    the greatest advantages for the particular environment. Self-shielded




                 Downloaded from Digital Engineering Library @ McGraw-Hill (www.accessengineeringlibrary.com)
                             Copyright © 2009 The McGraw-Hill Companies. All rights reserved.
                              Any use is subject to the Terms of Use as given at the website.