116   Improving Machinery Reliability


















                     Figure 3-28. Two-diameter mode shape for centrifugal impeller at 1,360 Hz determined
                     by modal analysis tests.










                            5000                                               30X


                                                                               I CIR
                                                                               4 DIA
                            4000
                         N
                         ::
                         I-
                         I
                         >
                         9  3000                                               3  DIA
                         Y
                         0
                         a:
                         W
                         U                                                     I5X
                         -1
                         U 3
                         P
                         1  2000
                         p:
                         W J
                         -I
                         L                                                     0  CIR
                                                                               2 DIA
                         z
                         U
                            I000
                                                                               1  DIA
                              0
                               0        2000     4000     6000      8000     10000
                                                 RUNNING  SPEED,  RPH
                                 Figure 3-29. Interference diagram for centrifugal impeller.
   139   140   141   142   143   144   145   146   147   148   149