Page 325 - Industrial Wastewater Treatment, Recycling and Reuse
P. 325
298 Industrial Wastewater Treatment, Recycling, and Reuse
Table 7.6 Designated best uses of water
Designated best use Class Criteria
Drinking water source without A 1. Total coliform organism
conventional treatment but MPN/100 mL shall be 50 or
after disinfection less
2. pH between 6.5 and 8.5
3. Dissolved oxygen 6 mg/L or
more
4. Biochemical oxygen demand
5 days 20 C, 2 mg/L or less
Outdoor bathing (organized) B 1. Total coliform organism
MPN/100 mL shall be 500
or less
2. pH between 6.5 and 8.5
3. Dissolved oxygen 5 mg/L or
more
4. Biochemical oxygen demand
5 days 20 C, 3 mg/L or less
Drinking water source after C 1. Total coliform organism
conventional treatment MPN/100 mL shall be 5000
and disinfection or less
2. pH between 6 and 9
3. Dissolved oxygen 4 mg/L or
more
4. Biochemical oxygen demand
5 days 20 C, 3 mg/L or less
Propagation of wildlife D 1. pH between 6.5 and 8.5
and fisheries 2. Dissolved oxygen 4 mg/L or
more
3. Free ammonia (as N)
4. Biochemical oxygen demand
5 days 20 C, 2 mg/L or less
Irrigation, industrial cooling, E 1. pH between 6.0 and 8.5
controlled waste disposal 2. Electrical conductivity at
25 C micro mhos/cm, max-
imum 2250
3. Sodium absorption ratio
maximum 26
4. Boron maximum 2 mg/L
Below-E Not meeting any of the A, B, C,
D, and E criteria
Source: Hydrology and Water Resources Information System for India & CPCB.