Page 184 - Solutions Manual to accompany Electric Machinery Fundamentals
P. 184
grid on;
The resulting plot is shown below:
6-21. A 460-V, 10 hp, four-pole, Y-connected, Insulation class F, Service Factor 1.15 induction motor has the
following parameters
R = 0.54 R 2 = 0.488 X M = 51.12
1
X = 2.093 X 2 = 3.209
1
P F&W = 150 W P misc = 50 W P core = 150 kW
For a slip of 0.02, find
(a) The line current I L
(b) The stator power factor
(c) The rotor power factor
(d) The rotor frequency
(e) The stator copper losses P SCL
(f) The air-gap power P AG
(g) The power converted from electrical to mechanical form P conv
(h) The induced torque ind
(i) The load torque load
(j) The overall machine efficiency
(k) The motor speed in revolutions per minute and radians per second
(l) Sketch the power flow diagram for this motor.
178