Page 184 - Solutions Manual to accompany Electric Machinery Fundamentals
P. 184

grid on;
                 The resulting plot is shown below:



































          6-21.  A 460-V, 10 hp, four-pole, Y-connected, Insulation class F, Service Factor 1.15 induction motor has the
                 following parameters
                         R  = 0.54            R 2  = 0.488        X  M  = 51.12 
                          1
                         X  = 2.093           X 2  = 3.209 
                           1
                         P F&W   = 150 W       P misc   = 50 W      P core   = 150 kW
                 For a slip of 0.02, find
                     (a)  The line current  I L

                     (b)  The stator power factor
                     (c)  The rotor power factor

                     (d)  The rotor frequency
                     (e)  The stator copper losses  P SCL

                     (f)  The air-gap power  P AG

                     (g)  The power converted from electrical to mechanical form  P conv

                     (h)  The induced torque  ind

                     (i)  The load torque  load
                     (j)  The overall machine efficiency 

                     (k)  The motor speed in revolutions per minute and radians per second
                     (l)  Sketch the power flow diagram for this motor.