Page 91 - Instrumentation Reference Book 3E
P. 91

76  Measurement of strain

          1-





          1




                                      .--    -7                 .--
          1. Roughening of the application area   2  Cleaning of the application area   3. Positioning of the strain gauge with tap















          4. Applying the adhesive   5. Spreading the adhesive   6. Pressing the strain gauge














          7. Soldering the strain gauge ribbons   0. Soldering and fixing the cables   9. Covering the measurement point
         Figure 4.8  Stages and installing gauges. Courtesy HBM.

         Strain


                  ridge    O"t.of.
                           balance
                           detector
                                                  -a
         Figure 4.9  Simple bridge circuit (quarter-bridge)   Figure 4.11  Half-bridge circuit

         Strain
             Leads                                Strain     Strain



                                                             Strain
                                                   Strain
                                                   wgs
         Figure 4.10  Quarter-bridge circuit with three long leads.   Figure  4.12   Full-bridge  circuit.
   86   87   88   89   90   91   92   93   94   95   96