Page 168 - Intro Predictive Maintenance
P. 168

Vibration Monitoring and Analysis  159




























                           Figure 7–27 Common magnetic mounts for
                           transducers.





















                               (a)          (b)            (c)
                         a.  Orientation is not 90° to shaft centerline.
                   b.  Measurement-point location is not always consistent.
                  c. Compressive load varies and may induce faulty readings.

                  Figure 7–28 Handheld transducers should be avoided when possible.



            maximum benefit from a predictive maintenance program. If this technique must be
            used, extreme care should be exercised to ensure that the same location, orientation,
            and compressive load are used for every measurement. Figure 7–28 illustrates a hand-
            held device.
   163   164   165   166   167   168   169   170   171   172   173