Page 100 - Introduction to Marine Engineering
P. 100

Boilers  87

                                    Flange
                                    connected
                                   / to boiler
                                    shell




         Packing ring






            Glass tube





















                         Drain pipe
                         led to
                         bilge
         Figure 4.11 Tubular  gauge glass


         up as a 'sandwich' of front and back metal plates with the glass plates and
         a centre metal plate between. Joints are placed between the glass and the
         metal  plate  and  a  mica  sheet  placed  over  the  glass  surface  facing  the
         water and  steam. The  mica sheet is an effective  insulation to prevent the
         glass  breaking  at  the  very  high  temperature.  When  bolting  up  this
         assembly, care must be taken to ensure even all-round tightening of the
         bolts.  Failure  to  do  this  will  result  in  a  leaking assembly and  possibly
         shattered  glass plates.
           In  addition  to the direct-reading  water level gauges,  remote-reading
         level indicators are  usually led to machinery control  rooms.
           It is possible  for  the  small water or  steam  passages  to block with scale
         or  dirt  and  the  gauge  will  give  an  incorrect  reading.  To  check  that
   95   96   97   98   99   100   101   102   103   104   105