Page 196 - Machinery Component Maintenance
P. 196
178 Machinery Component Maintenance and Repair
Setup 1-
Two-Indicator Face-and-Rim
Element
to be Adjusted
1 I
Setup 1A-
Two Indicator
Face-and-Rim with Stationary
Shaft Not Rotatable by Hand
n
Element
to be Adjusted
Figure 5-3. Two-indicator face-and-rim alignment method.
Setup 2-
Three Indicator Face-and-Rim
Element
to be Adjusted
I I
I 1
Figure 5-4. Three-indicator face-and-rim alignment method.