178   Machinery  Component Maintenance and Repair

                                                  Setup 1-
                                          Two-Indicator Face-and-Rim



                       Element
                       to be Adjusted


                       1             I




                                                 Setup 1A-
                                                 Two  Indicator
                                         Face-and-Rim with Stationary
                                          Shaft Not Rotatable by Hand
                                                 n

                       Element
                       to be Adjusted






                                  Figure 5-3.  Two-indicator face-and-rim alignment method.






                                                  Setup 2-
                                          Three Indicator Face-and-Rim




                       Element
                       to be Adjusted



                      I             I
                      I             1



                                 Figure 5-4.  Three-indicator face-and-rim alignment method.
   191   192   193   194   195   196   197   198   199   200   201