Table 3.5 (continued)
Treatment goal(s) Treatment approach Description Treatment application Limitations
Cooling Blowdown Boiler
tower water make-up
make-up water
water
Removal of dissolved Reverse osmosis Membrane system to separate X X Potential for fouling of RO membranes.
solids. organics, ions from solution basedon Brine requires treatment/disposal
pathogens reversing osmotic pressure
differentials
Nanofiltration and Pressure-driven membrane X X Potential for fouling of membranes.
ultrafiltration processes to remove Reject stream requires
constituents based on charge treatmentjdisposal