86     CHAPTER 6  DC Generators




                          (A)
                           +                                                     –

                                                                     series
                                  interpoles                         field
                                                armature









                                 regulator
                                                  shunt
                                                  field

                          (B)
                                             ++   – – –
                                                             COMMUTATING POLE


                                                                 MAIN POLE
                                                 S                           ++      – – –
                                             S      N
                                          N            N
                                                –
                                                   +
                                         N              S

                                          S            S
                                            S       N
                                                N





                         FIGURE 2.6.4
                         Interpoles. (A) A schematic and (B) series and commutating pole connections of a
                           compound-wound direct current generator configured to avoid magnetisation of the rotor
                         shaft (the shunt field winding is omitted). The series field is connected for clockwise
                           current flow, and the commutating poles for anticlockwise flow.
   94   95   96   97   98   99   100   101   102   103   104