Pipeline design for  pigging


        Pig-passage indicators

        Currently, pig-passage indicators of mechanical design  have the  longest
      track record. They are often regarded as unreliable, although any shortfall in
      performance  is usually due  to the  lack of preventive maintenance.
        Pig-passage indicators must be:

           bi-directional;
           flush with the internal pipe wall; and
           retractable and replaceable  under  pressure.

        Furthermore, pig-passage indicators can be equipped with a micro-switch
      for  remote  signalling. Such  applications  usually have  an  automatic  re-set
      mode, while mechanical passage  indicators are manually  re-set.

        Bends

        Bends for pigging should be of the following minimum radii:

                 4-in                  20D
                 6 and 8-in             10D
                 10-in and  above       5D

        Besides the minimum radius, the out-of-roundness should  also be limited
      to 5%.
        Special attention  should  be paid  to the internal diameter, as these  bends
      are usually hot-drawn from  heavy pipe wall material.
        The location of the bends should always allow a straight section  of at least
      three times nominal diameter  up- and down-stream.  In particular, 30° or 45°
      offset bends  should have a minimum straight length between them of 6ft for
     pipe diameters  to 24in, and 3D for diameters  of 24in and above.

         Valves

        Valves  should  be  specified  for  pigging  purposes  with  the  following
      requirements:

           full-bore  with  specified  minimum internal  diameter;
           guaranteed  100%  opening;