400                                                              Chapter 21


           -  Temporary condition

           1.  Normal operating condition


           The following conditions (ULS) with riser and floater in the normal intact status should be
           checked
           -  Environmental condition of  100 years wave plus 10 years current
           -  Floater at the neutral, far, near and transverse positions

           2.  Abnormal operating condition


           The following conditions  (PLS) shall be checked
           -  Riser and floater in intact condition with environmental condition of  10,000 years wave
              plus 10 years current.
           -  Loss of station-keeping ability
                 One mooring line or tendon failure
                 Floater is tilt due to damage
                 Dynamic position failure (drive-off or drift-off)
           -  Impact of dropped objects
           -  Partial loss of riser tension or buoyancy
           -  The  probability  and  consequences  of  fire,  explosion  and  riser  collision  should  be
              evaluated.


           3.  Temporary condition

           The following conditions (ULS) shall be checked
           -  Transportation condition
                 Consider loads to be applied during transportation
           -  Installation/n%-ieval condition
                 Varying amount of risers deployed
                 Riser filled with air or water
                 Environmental condition of  1 year wave (or 10 year) plus 1 year current
           -  Pressure test
                 Loads (especially pressure loads) during pressure test  shall be considered for riser
                 system design.
           -  Riser shut-down and start-up
                 Loads induced by shut-down and start-up shall be included in the fatigue evaluation.
           -  Pigging condition