Page 80 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 80

Installation, Maintenance, and Repair of  Horizontal  Pumps   65






                    1.11 20
                             I                                          I    n
                              DETAILED  CHECKLIST  FOR  ROTATING  EQUIPMENT:
                                          COUPLING  GUARD
                              MACHINE TAG  NO.
                                                                        DATE/BY
                    1,   MATERIAL   IS  12  GAUGE  GALVANIZED  STEEL.
                    2.   HINGED  INSPECTION  DOOR  PROVIDED
                    3,   GUARD  DOES  NOT  TOUCH  SHAFTS  OR  HOUSINGS.
                    4.   GUARD  ENCLOSES  COUPLING  TO  PRECLUDE
                         CONTACT  BY  PERSONNEL.
                    5.   GUARD  DOES  NOT  DEFLECT  WHEN  CONTACTED
                         BY  PERSONNEL.
                    6.  GAPS  BETWEEN  GUARD  AND  ACCESSIBLE  ROTATING
                         PARTS  NEVER  LARGER  THAN  1/2  INCH.





























                       DATE                                           FILE REFERENCE
                                    MACHINERY  RELIABILITY  PROGRAM
                    3/20/84                                         I  PAGE  I  OF  1
   75   76   77   78   79   80   81   82   83   84   85