Page 92 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 92

Installation, Maintenance, and Repair of %rtical Pumps   77


                         Deepwell Pump Shaft Adjustment
         Details of the upper portion of a hollow shaft motor are shown in Fig-
        ure 2-8. To adjust the axial position of a deepwell pump rotor:

          1.  Tighten the adjusting nut until the shaft starts to turn.  This is an
            indication that the shaft has stretched to compensate for the weight
            of the rotor and that the impellers have lifted clear of the bowls.

         2.  Engage the locking arm or otherwise hold the self release coupling
            against rotation. As the coupling is keyed to the shaft, the shaft is
            also held against rotation.











































        Figure 2-6. Totally enclosed fan-cooled ver-   Figure 2-7. Weather-protected type I (WPI)
        tical solid shaft normal thrust motor. (Cour-  vertical  hollow  shaft  high  thrust  motor.
        tesy US. Electrical Motors Division, Emer-  (Courtesy US. Electrical Motors Division,
        son Electric Company.)           Emerson Electric Company.)
   87   88   89   90   91   92   93   94   95   96   97