Page 394 - Practical Power System and Protective Relays Commissioning
P. 394

382  Index


            B                                Brushless excitation system, 38 39, 39f,40f
            Backup protections, 266          Buchholz protection, 272 273
              distance protection, 242       Buchholz relay, 50, 51f
              local backup and breaker failure protection,  Bus topology, 183
                 266 269                     Busbar layouts, 10 17
              primary protection zones of power system,  double busbar, double breaker arrangement,
                 267f                             14 16
              remote backup protection, 266, 268f  double busbar/one circuit breaker
            Balanced circulating current system, 261f  arrangement, 12
            Balanced voltage system, 262f      interconnected mesh corners arrangement,
            Bar primary type CT, 112              17
            Batteries, 157                     one and half breaker arrangement, 13 14
              acid concentration, 158          ring busbar arrangement, 13
              additional checks, 158           sectioning of busbar arrangement, 13
              charger, 160                     single busbar arrangement, 11
                                             Busbar protection, 251 252, 254f
               etting modes during battery charging,
                                               high-impedance circulating current
                 160 161
                                                  protection, 252
              charger commissioning tests
                                               IED, 199
               electrical tests, 30
                                               settings, 313
               visual checks, 30
                                                breaker failure protection, 319
              charging and discharging, 159 160
                                                two-section busbar with feeders and
              commissioning tests
               electrical tests, 30               incomers, 314f
               visual check, 30                 worked examples, 313 319
              DC power circuits, 157           testing and commissioning
              determining battery condition, 158  primary injection stability test, 351 355
              in high-voltage substations, 161 162  secondary injection tests, 350 351
              measurements, 159              Busbar protection. See Switchgear protection
              power sources, 157             Busbars, 143, 251
              safety considerations, 158       arrangement sectioning, 13, 16f
              specific gravity and acid concentration, 158  blocking scheme, 254f
            Bay level substation, 181          differential protection, 368
            Bearing failure protection, 250 251  synchronizing of synchronous generator
            BF. See Breaker failure (BF)          with, 41 42
            Biased differential relay, 312   Buses, 2
            Biomass energy, 34               Bushing-type CT, 112
            Bipolar links, 80 81, 81f
            Blind spots protection, 230 231  C
            Blind zone, 287
                                             Cable
            Blocking
                                               capacitance test, 75, 75f
              overreach transfer scheme, 225 226, 226f
                                               connection in GIS, 147, 149f
              voltage test, 358
                                               insulation resistance test, 75, 75f
            Boost charging, 161
                                               phase conductors, 73
            Breaker failure (BF), 199
                                               positive sequence impedance
              module test, 350
                                                  measurements, 76, 77f
              protection, 266 269, 319
                                               zero sequence impedance measurements,
               worked example for, 319 320
                                                  76, 77f
              relay
                                             Capacitance (C), 64 66, 69
               connection on overhead transmission
                                             Capacitive current, 64 65
                 line, 319f
                                             Capacitor voltage transformer (CVT), 126
               operation logic, 320f
                                               circuit, 127f
              scheme, 269f
                                               equivalent circuit, 127f
              time and total fault clearance time, 320f
                                               principle of operation, 126
   389   390   391   392   393   394   395   396   397   398   399