386  Index


            Distance protection (Continued)  Electrical characteristics of AC transmission
              worked examples, 289 294            lines, 69 70, 70f
            Distance relays, 366. See also Directional  Ferranti effect voltage rise, 71f
                 relays; Protection relays     loading of overhead transmission lines
              autoreclosing function in, 231 236  limit, 70f
              directionality test, 338f      Electrical commissioning tests
              inputs for correct measurement, 226 227  voltage transformer commissioning tests, 26
               neutral impedance compensation, 227  Electrical control, 92 94
              operating characteristic, 212 216, 212f,  Electrical discharge magnitude, 67
                 217f                        Electrical tests
               load encroachment in distance protection,  AC distribution panel commissioning tests,
                 215f                             29
               Mho distance relay characteristic, 213f  battery charger commissioning tests, 30
               simple plan impedance characteristic,  battery commissioning tests, 30
                 213f                          DC distribution panels commissioning tests, 29
               special distance relay characteristic, 216f  gas insulated switchgear commissioning
              overreaching, 217f                  test, 27
              protection zones, 214f           high voltage cables commissioning tests, 27
              switch to fault feature in, 230  power transformer commissioning, 25
            Distribution networks with radial reeders, 235  protection and control panels
            Distribution system, 1                commissioning tests, 28
            DOC. See Directional overcurrent (DOC)  Electromagnetic VT, operation principle of,
            Double busbar, double breaker arrangement,  123 125
                 14 16, 19f                  Electromechanical
            Double busbar/one circuit breaker  IDMTL relay, 194 196
                 arrangement, 12, 16f           time/current characteristic with different
            Double end break disconnect switch, 133,  time multiplier, 196f
                 135f                           types of inverse definite minimum time
            Double end break V-disconnect switch, 133,  characteristics, 196f
                 135f                          relays, 194, 194f, 195f, 325, 367 368
            Drop off/pickup ratio, 281       Electronic relays, 196 197
            DS. See Disconnect switch (DS)   End-to-end test, 326
            DT relays. See Definite time relays (DT  Energization
                 relays)                       commissioning procedures, 28 29
            Duty cycle, 86                     of substation test, 366 368
            Dy11 transformer differential protection, 280f  directional test, 367
                                                on-load stability test, 367 368
                                                synchronizing/phasing checks, 367
            E                                Energy, 32
            Earth fault                        biomass, 34
              protection, 202 204, 204f, 272, 321, 321f  geothermal, 34
              residual compensation factor, 293  hydroelectric, 35
            Earth wires, 69                    ocean or tidal, 34
            Earthing switch (ES), 133, 137f, 138 139,  primary, 32
                 143                           renewable, 32 35
              high-speed, 136 137, 143         solar, 32 33
            Earthing transformer               wind, 33 34
              protection, 275                ES. See Earthing switch (ES)
              sequence networks, 166, 168f   Excitation
            Economics, 190 191                 ceiling voltage, 41
            EI. See Extremely inverse (EI)     response, 41
            Electric field, 69                 system, 35