Page 402 - Practical Power System and Protective Relays Commissioning
P. 402

390  Index


            Manufacturer message specification (MMS),  O
                 183                         OC protection. See Overcurrent protection
            Maximum torque angle (MTA), 205       (OC protection)
            MCBs. See Miniature circuit breakers (MCBs)  Ocean energy, 34
            Megger tester, 72                OCT. See Optical current transformer (OCT)
            Merz-price differential protection, 263f  OFAF. See Oil forced air forced (OFAF)
            Message integrity, 184           Offset-Mho characteristic, 214 215
            Metering current transformer accuracy classes,  Offset-Mho distance relay, 244
                 109                         OFWF cooling. See Oil forced water forced
            Metrosils resistance. See Nonlinear resistance  cooling (OFWF cooling)
            MHI. See Machine-Human-Interface-Display  Ohm relay characteristic, 359
                 (MHI)                       Ohmic impedance, 174
            Mho characteristic, 212          Oil CB, 88, 89f
            Miniature circuit breakers (MCBs), 26  Oil forced air forced (OFAF), 51, 51f,52t
            Minimum bias, 296                Oil forced water forced cooling (OFWF
            Minimum zone protection, 230 231
                                                  cooling), 51, 52f,52t
            MMS. See Manufacturer message
                                             Oil natural air forced (ONAF), 52t
                 specification (MMS)
                                             Oil natural air natural (ONAN), 52t
            Moisture content, 91
                                             Old-type pilot wire differential protection
            Momentary overload test,
                                                  testing, 339 342
                 44
                                             On-load
            Monitoring relays, 189
                                               stability test, 367 368
            Monopolar links, 80, 80f           tap changer
            Motor faults, 320 321               using reactor, 54f
            Motor protection, 250 251           using resistor, 55f
              mechanisms, 133                  tests, 326
              setting, 320                   ONAF. See Oil natural air forced (ONAF)
               worked examples, 320 323      ONAN. See Oil natural air natural (ONAN)
            MTA. See Maximum torque angle (MTA)  One and half breaker arrangement, 13 14,
            Multishot reclosing, 232              18f
            MVA, 174                         Open circuit characteristic test, 43 44
                                             Open circuited secondary winding, CT, 111
                                             Opening time of CB, 232
            N                                Operating time
            National control center (NCC), 24, 93  in cycles, 85 86
              electricity control center, 379  of protection, 232
              SCADA system, 142              Optical current transformer (OCT), 115 118,
            Negative sequence, 163 164, 165f      128 129
            Negative-phase sequence current I 2 protection,  Optical high-voltage CTs, 116 118, 117f
                 246                         Optical instrument advantages, 116 118
            Negative-sequence principle,     Optical sensors, 129
                 228                         Optical voltage transformer (OVT), 115 118,
            Neutral impedance compensation, 227   128 129
            No-load                          Optimal coordination time, 201
              circuit losses test, 62        Out-of-step protection, 244 245, 246f
              current, 62, 63f                 for synchronous motors, 323
            Noise level test, 44             Out-of-step relay testing and commissioning,
            Nondirectional overcurrent, 202 203   359 360
              relays testing, 327 329          relay connection, 360
            Nonlinear resistance, 258, 303 304  test procedure, 360
            Nuclear generation stations, 1   Over speed test, 44
            Nuclear power stations, 31       Over-frequency protection, 247
   397   398   399   400   401   402   403   404   405   406   407