Page 405 - Practical Power System and Protective Relays Commissioning
P. 405

Index  393


             Puffer circuit breakers, 145, 146f  hydroelectric energy, 35
             Punch list, 24                    ocean or tidal energy, 34
             PV systems. See Photovoltaic systems (PV  renewable energy, 32 35
                  systems)                     solar energy, 32 33
             PVC. See Polyvinyl chloride (PVC)  wind energy, 33 34
                                              Reset ratio. See Drop off/pickup ratio
                                              Resin-embedded CT. See Bar primary type
             R                                    CT
             32R protection. See Power factor relay  Resistance (R), 69
                  protection                   earthing, 279
             Radial reeders, distribution networks with,  Resistor, on-load tap changer using, 55f
                  235                         Restitution unit, 141
             Radio interference, 69           Restricted earth fault protection (REF
             Rated accuracy limit factor, 109     protection), 240 241, 241f, 272, 272f
             Ratio error, 123 124             Reverse power protection, 243
             Ratio test, 119                  Reverse-phase sequence protection, 250
               voltage transformer, 131, 131f  Revolutions per minute (rpm), 31
             Reactance earthing, 279          Ring busbar arrangement, 13, 17f
             Reclaim time, 232                Ring main circuit overcurrent, 208
             Recovery voltage, 87             Ring-wound transformers. See Bar primary
             Reduced voltage test, 98             type CT
             REF protection. See Restricted earth fault  Rotor, 35
                  protection (REF protection)  earth fault protection, 246, 247f
             Reference voltage, 204           Routine maintenance tests, 325
             Regulating relays, 189           rpm. See Revolutions per minute (rpm)
             Relay operating time (T R ), 195, 201, 283
               test connection, 344f
             Relays, 189, 194 201             S
               characteristic test, 328 329   Safety equipment, 158
                differential, 346f            SAS. See Substation automation system (SAS)
                of directional OC relay, 331f  SAT. See Site acceptance test (SAT)
                Ohm, 359                      Saturation factor. See Accuracy limit factor
               circuit, 302 303, 305f, 315f       (ALF)
               classification                 SC. See Short circuit (SC)
                on characteristics, 190       SCD. See Substation configuration description
                on function, 189                  (SCD)
                on input quantities, 189 190  Schematic/elementary diagram, 9
                on principals or structures, 190  SCL. See Substation configuration language
               connection, 205                    (SCL)
               construction and operation of  SCR. See Short-circuit ratio (SCR)
                  electromechanical IDMTL, 194 196  Seal in “self-holding” circuit, 92
               IEDs, 197 201                  Secondary energy, 32
               inverse characteristic, 195f   Secondary injection tests
               overcurrent, 201 209            Busbar protection, 350 351
               static protection, 196 197      distance protection testing and
             Reliability, 191                     commissioning, 332 338
             Remote backup                     overcurrent relay
               protection, 266, 268f             directional overcurrent relay testing and
               relays, 266                        commissioning, 330 331
             Renewable power systems, 32 35      nondirectional overcurrent relays testing,
               biomass energy, 34                 327 329
               geothermal energy, 34           protective relays, 325 326
   400   401   402   403   404   405   406   407   408   409   410