Page 403 - Practical Power System and Protective Relays Commissioning
P. 403

Index  391


             Overall differential protection, 236  Phase unbalance protection, 323
             Overcurrent protection (OC protection), 242,  Phase-to-earth faults, 227
                  242f. See also Feeder backup  Phase-to-phase fault, 171, 171f, 176f, 177, 227
                  overcurrent protections     Phasing check, 72, 73f
               settings, 281 282              Phasing process, 367
                of high-voltage transmission line, 282f  Photovoltaic systems (PV systems), 32, 33f
                transmission line overcurrent protection,  Pickup/drop off test, 328
                  282 283                     Pilot wire protection, 262 263
               transformer, 271, 283 284, 283f  PLC. See Power line carrier (PLC)
             Overcurrent relays. See also Distance relays;  Plug setting multiplier (PSM), 195, 282 283
                  Protection relays           Polarity test (PT), 119, 130 131, 130f, 153
               directional relays, 204 208    Polarization Index Test, 43
               earth fault protection, 204    Polarizing signal, 204
               IEC curves and ANCI/IEEE curves  Pole slipping protection. See Out-of-step
                  overcurrent relay characteristic, 209  protection
               nondirectional overcurrent and earth fault  Poly-phase transformers, 54 55
                  protection, 202 203         Polyvinyl chloride (PVC), 71
               principles of time/current grading, 203 204  Positive sequence, 163, 165f
               secondary injection tests, 327 331  Postfault times, 142
             Overexcitation, 56 58            POTT. See Permissive overreach transfer trip
             Overfluxing, 58                      (POTT)
             Overhead                         Power
               AC lines, 69 70                 angle of synchronous machines, 41
                electrical characteristics of AC  conductors, 69
                  transmission lines, 69 70    factor relay protection, 248
               transmission, 69                sources, 157
             Overloading protection, 247, 250, 311, 323  Power line carrier (PLC), 263 265
               transformer, 271               Power stations
             OVT. See Optical voltage transformer (OVT)  fault recorders in, 141
             Oxygen content, 91                generator connection in, 41, 42f
                                              Power swing blocking
                                               relay, 228, 229f
             P                                 settings, 293 294
             Pantograph disconnect switch, 133, 136f  Power system, 1, 3f, 189
             Paper-insulated oil-filled cables, 72  components, 2
             Parallel lines, distance protection setting for,  theory, 19
                  219 220, 219f, 220f          distribution system, 1
             Partial discharge measurement, 66 67  fault calculations
             Percentage impedance (Z%), 166      basic system relationships, 163
               of transformer, 53, 53f           sequence impedance networks, 165 170,
             Permissive overreach scheme, 223, 223f, 224f  166f
               weak infeed in, 220, 221f         symmetrical and unsymmetrical
             Permissive overreach transfer trip (POTT),  components, 163 165
                  220                            symmetrical three-phase fault analyses,
             Permissive underreach scheme, 222, 222f,  170 173
                  223f                           worked examples, 173 177
             Petersen coil earthing, 279       IEEE device numbers and functions for
             Phase error, 123 124                 switchgear apparatus, 2 4
             Phase fault protection, 321       loads, 1 2
             -Phase rotation protection, 323   power generation, 1
             Phase sequence test, 44           system voltages, 2
             Phase to phase to earth fault, 171 172, 172f  transmission, 1, 210
   398   399   400   401   402   403   404   405   406   407   408