Page 467 - Practical Well Planning and Drilling Manual
P. 467

Appendix NEW! revised 11/00/bc  1/30/01  3:29 PM  Page 443








                                     Formation Integrity Test Recommended Procedure  [          ]
                                                                              Appendix 2



                       Table A-1  Leakoff Test Example

                         Well: Test 1
                           Volume Pumped,    Stabilized Pressure,   Pressure Increase,  Comments
                                 bbl               psi              psi
                                 0                 0                 0
                                 0.5               50                50
                                 1.0              150               100
                                 1.5              250               100
                                 2.0              350               100
                                 2.5              420                70         Leakoff
                         Bled off; 2.1 bbls returned













































                                                     443