Page 402 - Reciprocating Compressors Operation Maintenance
P. 402

Safety  in Operation and Maintenance  387


           Only  one  type  of  plastic  pipe  has  been  approved  for  use  with com-
         pressed  air. That pipe,  says the bulletin, is acrylonitrile-butadiene-styrene
         (ABS) and the pipe  is marked  as approved for compressed air supply. By
         law, employers  in Washington must protect  their workers by avoiding the
         use  of  unapproved  PVC  pipe  in  compressed  air  systems.  Existing  sys-
         tems  using  PVC  piping  must  be  completely  enclosed,  buried,  or  ade-
         quately  guarded  according  to  specifications  approved  by  a  professional
         consulting engineer.