284 Chapter Fourteen
TABLE 14.6 Temperature of Dry and Saturated Steam (Metric) (Continued)
To obtain superheat in degrees Celsius, subtract temperature given in tabulation from
total initial temperature.
p g , bar t sat , °C p g , bar t sat , °C p g , bar t sat , °C
6.5 168 22.0 220 50 265
7.0 171 22.5 221 51 266
7.5 173 23.0 222 52 268
8.0 176 23.5 223 53 269
8.5 178 24.0 224 54 270
9.0 180 24.5 225 55 271
9.5 182 25 226 56 272
10.0 184 26 228 57 273
10.5 186 27 230 58 275
11.0 188 28 232 59 276
11.5 190 29 234 60 277
12.0 192 30 236 61 278
12.5 193 31 238 62 279
13.0 195 32 239 63 280
13.5 197 33 241 64 281
14.0 198 34 243 65 282
14.5 200 35 244
15.0 201 36 246
(a)
Figure 14.15 Superheat correction factors for single-valve, single-stage steam turbines. (Elliott
Company, Jeannette, Pa.)