286   Chapter Fourteen


































            Figure 14.17 Inlet size requirements for single-valve, single-stage steam turbines, metric
            units. (Elliott Company, Jeannette, Pa.)


              Step 6: Determine corrected steam rate by formula:
                                        base steam rate        (hp + hp loss)
             Corrected steam rate =                          ×
                                   superheat correction factor      hp

                or

                            Base steam rate   (kW + kW loss)
                                            ×
                                  SCF               kW
              Step 7: Determine steam flow (SF) by the formula:

                          Steam flow = corrected steam rate × hp

                or
                          Steam flow = corrected steam rate × kW

              Step 8: Determine the required inlet size using Fig. 14.16 or 14.17,
              knowing SF and turbine inlet pressure and temperature.