Page 180 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 180

Brockenbrough_Ch04.qxd  9/29/05  5:09 PM  Page 4.8



                                          BUILDING CODES, LOADS, AND FIRE PROTECTION*


                   4.8  CHAPTER FOUR

                   TABLE 4.3 Minimum Uniformly Distributed Live Loads, L o , and Minimum Concentrated Live Loads
                                                                                     2
                                                                                2
                                   Occupancy or use                    Uniform lb/ft (kN/m )  Conc. lb (kN)
                   Apartments (see residential)
                   Access floor systems
                     Office use                                             50 (2.4)           2000 (8.9)
                     Computer use                                          100 (4.79)          2000 (8.9)
                   Armories and drill rooms                                150 (7.18)
                   Assembly areas and theaters
                     Fixed seats (fastened to floor)                        60 (2.87)
                     Lobbies                                               100 (4.79)
                     Movable seats                                         100 (4.79)
                     Platforms (assembly)                                  100 (4.79)
                     Stage floors                                           150 (7.18)
                   Balconies (exterior)                                    100 (4.79)
                     On one- and two-family residences only, and not exceeding  60 (2.87)
                         2
                              2
                     100 ft (9.3 m )
                   Bowling alleys, poolrooms, and similar recreational areas  75 (3.59)
                   Catwalks for maintenance access                         40 (1.92)           300 (1.33)
                   Corridors
                     First floor                                            100 (4.79)
                     Other floors, same as occupancy served except as indicated
                   Dance halls and ballrooms                               100 (4.79)
                   Decks (patio and roof)
                     Same as area served, or for the type of occupancy accommodated
                   Dining rooms and restaurants                            100 (4.79)
                   Dwelling (see residential)
                                                 2
                                                         2
                   Elevator machine room grating [on area of 4 in (2580 mm )]                  300 (1.33)
                                                           2
                                                    2
                   Finish light floor plate construction [on area of 1 in (645 mm )]            200 (0.89)
                   Fire escapes                                            100 (4.79)
                     On single-family dwellings only                       40 (1.92)
                   Fixed ladders                                                              See Sec. 4.4
                   Garages (passenger vehicles only)                       40 (1.92)            Note (1)
                     Trucks and buses                                               Note (2)
                   Grandstands (see stadium and arena bleachers)
                   Gymnasiums, main floors, and balconies                100 (4.79) [Note (4)]
                   Handrails, guardrails, and grab bars                            See Sec. 4.4
                   Hospitals
                     Operating rooms, laboratories                         60 (2.87)           1000 (4.45)
                     Private rooms                                         40 (1.92)           1000 (4.45)
                     Wards                                                 40 (1.92)           1000 (4.45)
                     Corridors above first floor                             80 (3.83)           1000 (4.45)
                   Hotels (see residential)
                   Libraries
                     Reading rooms                                         60 (2.87)           1000 (4.45)
                     Stack rooms                                        150 (7.18) [Note (3)]  1000 (4.45)
                     Corridors above first floor                             80 (3.83)           1000 (4.45)
                   Manufacturing
                     Light                                                 125 (6.00)          2000 (8.90)
                     Heavy                                                 250 (11.97)        3000 (13.40)
                   Marquees and canopies                                   75 (3.59)
                   Office buildings
                     File and computer rooms shall be designed for heavier loads
                     based on anticipated occupancy
                     Lobbies and first floor corridors                       100 (4.79)          2000 (8.90)
                     Offices                                               50 (2.40)           2000 (8.90)
                     Corridors above first floor                             80 (3.83)           2000 (8.90)
                                                                                               (Continued)

                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.
   175   176   177   178   179   180   181   182   183   184   185