Page 160 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 160

Brockenbrough_Ch03.qxd  9/29/05  5:05 PM  Page 3.92



                                                        CONNECTIONS


                   3.92  CHAPTER THREE

                                 WEB CRIPPLING (UNDER NORMAL LOAD H C )

                                                                24 5 .   129  15 .   29 000 50 2 07
                                                                                    ×
                                                                       .
                                                                                ,
                                                                                       × .
                                                   ×
                                                              +
                                                            
                                                            2
                                                         .
                                          φR wcp  = 0 75 0 8 .  ×1 2913     
                                                 .
                                                                16 7 .   207     129
                                                                       .
                                                                                     .
                                                        >
                                               = 4820 kips 220 kips  OK
                                 WEB SHEAR. The horizontal force, H c , is transferred to the column by the gusset-to-column con-
                               nection and back into the beam by the beam-to-column connection. Thus, the column web sees H c =
                               220 kips as a shear. The column shear capacity is
                                           φR v = 0.9 × 0.6 × 50 × 1.29 × 16.7 = 583 kips > 200 kips  OK
                                 Gusset-to-Beam Connection.  Design for 349 kips shear and 4205 in⋅kips moment.
                                 GUSSET STRENGTH. Design strength for the gross section shear is
                                                 f v = 349/(1.5 × 30) = 7.76 ksi < 19.4 ksi  OK
                               Design strength for flexure is
                                                                 2
                                               f b = (4205 × 4)/(1.5 × 30 ) = 12.5 ksi < 32.4 ksi  OK
                                 WELD OF GUSSET-TO-BEAM FLANGE
                                                    .
                                             f peak  = 776 2  +125 .  2  ×  15 .  = 11 0 .   kips/in
                                                                2
                                              θ  =  atan  12 5 .    = 58 2 .  °
                                               w
                                                        .
                                                       776 
                                                  1                         ] 15 .
                                              f ave  = [ 776 2  +125 .  2  + 776 2  +125 .  2  = 11 0 .   kips/in
                                                                   .
                                                      .
                                                  2                          2
                               Since 11.0/11.0  = 1.0  < 1.25, the weld size based on the average force in the weld is 1.25f ave .
                               Therefore,
                                                                    .
                                                      D =     11 0 .  ×1 25  = 710
                                                                              .
                                                                     .
                                                                    15
                                                          .
                                                         1 392 1 [  + 0 5 . sin ( 58 2 . )]
                                    1
                               Use a  / 2-in fillet weld.
                                 Beam Web
                                 WEB YIELD. Although there is no axial component, the couple M B = 4205 in⋅kips is statically
                               equivalent to equal and opposite vertical shears at a lever arm of one-half the gusset length or 15 in.
                               The shear is thus
                                                           V =  4205  = 280 kips
                                                            s
                                                                15
                               This shear is applied to the flange as a transverse load over 15 in of flange. It is convenient for analy-
                               sis purposes to imagine this load doubled and applied over the contact length N = 30 in. The design
                               web yielding strength is
                                      φR wy = 1.0 × 50 × 0.47(30 + 5 × 1.27) = 854 kips > 280 × 2 = 560 kips  OK



                           Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                      Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                       Any use is subject to the Terms of Use as given at the website.
   155   156   157   158   159   160   161   162   163   164   165