Page 204 - The Art and Science of Analog Circuit Design
P. 204

Jim Williams


        particularly useful in evaluating display (as opposed to simply the lamp)
         luminosity under various drive conditions. The calibrated output permits
                                             2
         reliable correlation with customer results.  The light tight measuring head
        allows evaluation of emittance evenness at various display locations. This
         capability is invaluable when optimizing lamp location and/or ballast
        capacitor values in dual lamp displays.
           Figure 11-B2 shows the photometer in use evaluating a display.



         2. It is unlikely that customers would be enthusiastic about correlating the "brights" units produced
           by the aforementioned glometer.



















































        Figure 11-B2.
        Apparatus for calibrated photometric display evaluation. Photometer (upper right) indi-
        cates display luminosity via sensing head (center). CCFL circuit (left) intensity is con-
        trolled by a calibrated pulse width generator (upper left).

                                                                                       185