Page 162 -
P. 162

rrnq   '  ::::::::   I ]HHr  Special  Applications
                                   _

                 o   Calculate   stock   head-capacities   by   multiplying   water
                     performances  by  the  correction  factors.  Calculate  stock
                     efficiencies using equivalent water BHP values.

                                     GPM(stock )  x  Total  Head(stock)  x  SP.  Gr.
                         %Eff.(stock  )   =
                                             3960  x  BHP(stock)


                     NOTE: BHP  (Stock)  =  BHP  (Water)
                     Plot  the  curve  for water  and  the  approximate  stock  performance
                 o
                     as in Figure  8.15.


                                    l:T.~.:... 7 :.: :I: i:: 2::~:  '  .  :  ::.:  :~:I: :.:i:i: i: :::::":::;  I:  : .........  : .... .APPROXIMATE   :
                       ::.I"::?::HEAD:I6V8 '~: DIA:   ,  ..::.:..~{....:::: ..:  :  I:  !  .i   i  .l::i  : "  ::::::::I:  _.i::  :  C;HARACTERISTIC  CURVES  :
               t30    84
























                      0     2.00.   400   600   800    1000   1200  -:   1400
                                           GALLONS  PER  MINUTE
              Figure  8.15: Approximate  characteristic  curves of centrifugal  pump  (Reproduced  with
              permission  of Goulds  Pumps,  ITT Industries)
















                                                                .........   141
   157   158   159   160   161   162   163   164   165   166   167