Page 216 -
P. 216
Troubleshooting
9 Upgrade the material selection
9 Change to a mechanical seal
Shaft deflection
9 Check for low flow. (See Figure 11.3)
9 Increase the shaft strength. (See 11.4.2.2)
Shaft run-out too high
9 Install a new shaft
Worn stuffing box
9 Install a new stuffing box
Mis-aligned lantern ring
9 Repack the pump properly
9 Replace stuffing box if necessary
9 Skills training needed
Too many rings of packing
9 Repack the pump properly
9 Skills training needed.
Wrong size of packing
9 Repack the pump properly.
9 Sldlls training needed.
Rings incorrectly cut
9 Repack the pump properly
9 Skills training needed.
Poor start-up procedures
9 Knowledge training needed
Badly installed packing
9 Repack the pump properly
9 Skills training needed
11.5.7 Mechanical seal - general
Temperature problem
9 Improve environmental controls
195 !