Page 216 -
P. 216

Troubleshooting


                9  Upgrade  the material selection
                9  Change  to  a mechanical seal
               Shaft deflection
                9  Check for low flow.  (See Figure  11.3)
                9  Increase the  shaft strength.  (See  11.4.2.2)

               Shaft run-out too high
                9  Install a new shaft
               Worn stuffing box
                9  Install a new stuffing box
               Mis-aligned lantern ring

                9  Repack the pump  properly
                9  Replace  stuffing box if necessary
                9  Skills training needed
               Too many rings of packing

                9  Repack the pump  properly
                9  Skills training needed.
               Wrong size of packing
                9  Repack the pump  properly.
                9  Sldlls training needed.

               Rings incorrectly cut
                9  Repack the pump  properly
                9  Skills training needed.
               Poor start-up procedures
                9  Knowledge training needed
               Badly installed packing

                9  Repack the pump  properly
                9  Skills training needed

              11.5.7  Mechanical  seal -  general

               Temperature problem
                9  Improve  environmental  controls




                                                                          195   !
   211   212   213   214   215   216   217   218   219   220   221