Page 219 -
P. 219
The Practical Pumping Handbook .................... ~ ". ..... -__ - ~ -
Zero wear track
9 Improve seal installation to contact faces
9 Change to large bore seal chamber
Severe uniform wear
9 See Bearings, Chapter 11.5.5
9 Check for excessive Pressure-Velocity value
9 Improve environmental controls
Intermittent wear pattern
9 Change to flexible mounted stationary face
9 Ensure faces are flat when installed
9 Installation training needed
Edge chipping
9 Check pump operation for vaporization
9 Improve environmental controls
9 Increase the shaft strength. (See 11.4.2.2)
Heating checking
9 Check for pumpage for excessive temperatures
9 Check for excessive Pressure-Velocity value
9 Check for dry running of pump
9 Upgrade the material selection
9 Improve environmental controls
Coking or Crystallization
9 Check for pumpage for excessive temperatures
9 Change to large bore seal chamber
9 Improve environmental controls
9 Upgrade the material selection
Blistering
9 Upgrade the material selection
Corrosion
9 Upgrade the material selection
! 198