74    Cha pte r  T w o


           Maximum Existing  Depth of
                                             Required DR (d/t)
           Pipe Ovality    Pipe (Soil
           Percentage      Cover) (ft)  E  = 250,000 psi  E = 400,000 psi
                                       i              i
           2%                4'–10'   DR57           DR66
                            11'–15'   DR48           DR56
                            16'–20'   DR42           DR49
                            21'–24'   DR39           DR46
           5%                4'–10'   DR52           DR61
                            11'–15'   DR44           DR52
                            16'–20'   DR39           DR45
                            21'–24'   DR36           DR42
           10%               4'–10'   DR45           DR52
                            11'–15'   DR38           DR45
                            16'–20'   DR33           DR39
                            21'–24'   DR31           DR36
          Gravity Pipe, Fully Deteriorated Condition

                                        Designed by:
                                        Checked by:
                                        Date:         09/29/2009
           Project name   Design example—48 in. diameter
           Location       Anytown, U.S.
           Client
          Design Criteria
           Pipe mean inside diameter (in.)         48.00 in.
           Ovality (q) %                           2 %
           Pipe minimum inside diameter (in.)      47.04 in.
           External water (H , ft above invert)    12.00 ft*
                        w
           External water (H , ft above crown)     8.00 ft*
                        w
           Depth of soil (H, ft above top of pipe)  16.00 ft
           Soil modulus (E ) psi                   1000 psi
                       s
           Liner pipe flexural modulus (E) psi     250,000 psi
           Liner pipe flexural strength (S) psi    4500 psi
           Reduction to account for long-term effects (%)  50%
           Soil density (w) lb/ft³ (Table 2.11)    120 pcf
           Live load (concentrated) lb (p)         16,000 lb
           Live load (distributed), (p) psf        0 psf
           Distributed load width, (X) ft          8 ft
           Distributed load length, (Y) ft         20 ft
           Factor of safety, N                     2.00
           *Plus internal vacuum if applicable