Page 345 - Trenchless Technology Piping Installation and Inspection
P. 345

Monetary   Penalties  No deduction,   assuming adequate   thickness is   achieved.  No deduction,   assuming adequate   thickness is   achieved.







                  Repair Types  Removal of wrinkles   (fins) and coat area   with approved epoxy   material. Trim to   within 1/4 in. of   pipe wall surface.  N/A









                  Requirements  Repair if exceeding   5 percent of   nominal diameter   of existing pipe   along top of the   pipe (from 9 to   3 o’clock position)   and 3 percent of   nominal diameter   of existing pipe   along bottom of the   pipe (from 3 to   9 o’clock position).   No action required.


                Repair


                  Accepted Tolerance  Generally  5 percent of   nominal diameter   in top and 3% of   nominal diameter   in bottom of the   existing pipe   is tolerated,   assuming such   does not impede   the normal flow   characteristics.∗  The wrinkles are   relatively minor   and should not   impede the flow   characterist













                  Probable Cause  Undersized or   deteriorated localized  section of existing pipe.  The corrugated   pipe may have been  measured incorrectly  at the inside diameter   or high point of the   corrugations, rather  than the center of the   corrugations.











                  Defects  Wrinkles/fins/  folds (LW)/(LF)





        300
   340   341   342   343   344   345   346   347   348   349   350