Page 225 - Troubleshooting Analog Circuits
P. 225

212                                                            Index


            funny, amount of, 5          snubber, 37-38             LM3xx. See LMlxx (Linear Monolithic
            fuses. See also circuit breakers, 33-34,   steel, 34.38       ICs made by National)
                  140,164                test conditions, 35-37     LMIO, 21,24,96,105,  188
             fatigue failures, 38        turns. See windings        LM12.105
             ratings, AC, 34             used in switchmode regulator, 138,   LM35 temperature sensor IC, 24.25
             ratings, DC, 34                  139,183-184           LMlOl/LMl01A/LM301A,  77,96,188
            FVCs. See frequency-to-voltage con-   windings, 35-36   LMl07/LM307,96,188
                  verters                wire losses, 35,38         LM108LM308,72.96,118,188,205,
                                        instrumentation amplifier, 182    207
            Giles, Martin, 44           insulation leakage, measurement.  See   LMl 10/LM310.100,21,116
            gimmick. See under capacitors     under cwent detector   LM111/LM311,113,115,194
            glass-epoxy beams, low-picofarad   integrator, operational amplifier circuit,   LM117LM317, 10,11,37-38,53-54,
            "glitches."  See under digital ICs   89,99.104,153            80, 105, 106, 130, 136,177,
            grid-dip meter, 22, 109     intelligence, artificial (AI), 1 1. See also   178,190-192
            ground, 57, 129-130,145,  156.    under stupidity, artificial   LM120/LM320,130, 179
                  161-162.  See also under   intelligence, genuine, 1 1. See ulso   LM122LM322.120
                  printed circuit boards. See   stupidity, genuine   LM123LM323.58
                  also under analog-to-digital   Interconnection Produp Inc., 185   LM124LM324,96.115-116,124,190,
                  converters            intermittent problems+echniques  for   LM129/LM329,18,71,135
            ground loops, 25,63, 110,129-130,  156   solving, 15,32,50,60,63,   LM131/LM331,21,21,131,148-149,
                                              121-122.143-144,  153,170,   206
            hrb, 78-79                        175                   LMl33LM333, 105
            HA2525.81                                               LM136/LM336,7 1
            hacksaw, 9.23               judgment, 12.56.81.87       LM137LM337.105-106,178
            hair-dryer, 23                                          LM138/LM338.105,137,178
            hairline opens, 8,51        Kelvin connections, 57-58,59,80,  178   LM139/LM339,111, 115-116
            hairline shorts, 24.5 1      4-terminal resistors, 57-58   LM140LM340.178
            hammer, 9,38                 examples in tests, 58      LM149/LM349.102,190
            hand tools, 14,23            Kelvin clips, 57           LM15O/LM350,37,105,137,178
            heat sinks, 82. 116,135,165,178,180   Kelvin sockets, 57-58.  198   LM158LM358.96, I15
             bolts just right, 83, 180   remote-sense regulators, 98.59   LM168/LM368,105
             bolts too loose, 82, 180   kilovolts, 27               LMl69/LM369,71,105,135
             bolts too tight, 83. 180   Koontz, J. 162              LM I85LM385.7 1
             burrs between heat sink and tran-                      LM192LM392, 116
                  sistor, 83            Lamoureux, Richard, 170     LMl93LM393.115
             just right, 83,84          laser, 6                    LMl94/LM394,24,78-79,196
             too big, 84                latches, 18,60, 108, 117-1 18, 140, 156   LM196/LM396,80,105, 178
             too small, 82,86,106,135    comparator latches, 11 3   LM199/LM399,71,135
            Heath Company, 22,59, 107, 109   current-limited power supplies, 18, 18   LM555,120
            Hoffman, John Paul, 167      destructive, 118           LM612,113,  115
            humidity, 10,55,61, 147      non-destructive, 118       LM615, 113
            hypothesis, 6, 107           power supply sequencing, 118   LM709,104,116
            hysteresis. See under comparators,   storage scopes, 15   LM723,179,181
                  problems with         leakage, current, 10,4142,44,52-56,   LM74 I, 18,18,77,90,97,188
                                              6142.65-70.81.121,  128,   LM2575, 139,183,183, 185
            impedance analyzer  or bridge, 25,30,35   177           LM2576,139
            identical, 168              leakage currents, measurement.  See   LM2577.139
            inductance, 110,116,13~139,144,   current meter         LM2578.139
                  148,162,183-185,191-193.   leakage inductance, 35   LM2579.139
                  207                   LEDs. See light-emitting diodes   LM3045,79
            inductors, 34-39,  138.  See ulso trans-   Lembo, Dr. Nicholas, 11-12   LM3046,104,196
                  formers and relays    LF147/LF347,116,190         LM3086.79
             air, 34                    LF 155LF355.188-189         LM3524, 139,140,184,185
             air gaps, 35               LFl56/LF356,18,93,96,97,188-189   LM6 12 lLM632 1.1 17
             beads. 8.37.84.87.109,  162   LF157LF357, 102,189      LM616ULM6361.96,  100, 189
             core material, 34-35       LF198LF398, 132,159         LM6325, I17
             core losses, 35,38         LF351,116,188               LM6361. See LM6161
             ferrite, 35-39             LF400, LF401.91.189         LM7800,178
             incoming inspection of, 36   LF411,188                 LM7900,179
             "kick" from, 36-37         LF6197, 132                 LMC555,120
             materials, 3C39            light-emitting diodes (LEDs), 73-74,   LMC660,53,81,96,190
             measurements of:                 196,197. See also diodes   LMC662,81,96,159,190
               ohmmeter and problems of, 35-36,   DEADs (Darkness-Emitting Arsenide   lock washers, 63. 170. 173
                  38                          Diodes), 74           locomotives, 3,7
               inductance meter, 35-36   polarity, 73               logarithmic amplifier.  See current
               Q-meter, 35               reliability, 73                  meter, logarithmic
             R-C damper, 37              uniformity, 72             logarithmic current detector. See under
             saturation, 35-36.38       list of things that can't be causing the   current meter, logarithmic
             shorted turn, 35.38              problem, 3.7          logic analyzer, 25, 123, 140
   220   221   222   223   224   225   226   227   228   229   230