Page 290 - Valve Selection Handbook
P. 290

Sizing Pressure Relief  Devices           277

                                 3
             Volumetric  flow—Nm /h






            where









            For values of F refer to Figure 7-1.

          Sizing Equations  for  Liquid  Flow

          Customary  Mixed Imperial  Units

            Volumetric flow—US gpm








          Customary  Mixed SI Units

            Weight  flow—kg/h








          Rupture  Disc  Sizing  for  Violent Pressure Excursions in
          Low-Strength   Containers

            Sizing data on vent panels for explosion venting are based  on informa-
          tion  from  simple  models  and  data  obtained  from  vapor  and  dust explo-
          sions  in  vessels  fitted  with  explosion  relief.  The  recommended  sizing
          procedures  are contained in publications of nationally recognized organi-
          zations.  The  widely recognized  publications  in  the  U.S.  are  the  NFPA
   285   286   287   288   289   290   291   292   293   294   295