Page 294 - Valve Selection Handbook
P. 294

Table A-2.1 Section 1 Requirements
 PRESSURE R ELIEF DEVICE OPERATING REQUIREMENTS
                                                        IO
 ALLOWABLE VESSEL                                       00
 OVERPRESSURE  SET PRESSURE  TOLERANCE                  o
 (ABOVE MAWP OR VESSEL  SPECIFIED PRESSURE  WITH RESPECT TO SET  REQUIRED
 APPLICATION  DESIGN PRESSURE)  SETTINGS  PRESSURE  SLOWDOWN
 SECTION 1  One valves MAWP  ±2 psi up to and including 70 psi  Minimum:  2% of set pressure or
 6% (PG-67.2)*               2 psi whichever is greater
 Others up to 3% above MAWP  ±3% for pressures above 70 psi up
 (PG-67.3)  to and including 300 psi  Maximum:  4% of set pressure or
                             4 psi whichever is greater, with
           ±10 psi for pressures above 300  some exceptions
           psi up to and including 1000 psi  (see PG-72)
           ±1 % for pressures above 1 000 psi
          L  (PG-72.2)
 Forced Row Steam  20% (PG-67.4.2)  May be set above MAWP; Valves  Same as above  Maximum:  10% of set  pressure
 Generators  must meet overpressure  (PG-72.2)  (PG-72)
 requirements (PG-67.4.2)                               s
 *Note: References  in parentheses are to Code paragraphs.  1 psi = 6.89  kPa  »••
                                                        $
                                                        SP
 Table A-2.2 Section III  Requirements
                                                        I
 PRESSURE RELJEF DEVICE OPERATING RE< aUIREMENTS        I
 ALLOWABLE VESSEL
 OVERPRESSURE  SET PRESSURE TOLERANCE                   s
 (ABOVE MAWP OR VESSEL  SPECIFIED  WITH RESPECT TO SET  REQUIRED
 APPLICATION  DESIGN PRESSURE)  PRESSURE SETTINGS  PRESSURE  SLOWDOWN  3
 SECTION III  10% above the design pressure of  One valve £ design pressure  Safely Valves  Safety Values
 any component within the  ±2 psi for pressures up to and  95% of set pressure (maximum),  I
 NB  pressure retaining boundary of the  Additional valves higher provided  including 70 psi  or as specified in design
 NC  protected system  limits on overpressure are  specification  &
 ND  maintained  ±3% for pressures above 70 psi up  (NB-7512.3)
 NE  (NB-7410)  to and including 300 psi
 (ND-7311b)  (NC-7410)
 (ND-7410)  ±10 psi for pressures above 300  As specified in design specification
 Overpressure may not exceed the  psi up to and including 1000 psi  (NC-7S12.3)
 service or test limits specified in  Valves must be set to operate  (ND-7512.3)
 the Design  Specification  within overpressure limits  ±1% for pressures above 1000 psi  (NE-7512.2)
 (NE-7110a)  (NE-7410)  (NB-7512.2)  (ND-7512.2)
          (NC-7512.2)
          Safety Relief and Relief Valves
          ±2% psi for pressures up to and  Safety Relief and Relief Valves
                            As specified in design specification
          including 70 psi
          (NB-7513.1a)  (ND-7513.1a)  (NB-7513.2)
                            (NC-7513.2)
          (NC-7513.1a)  (NE-7512.1a)
                            (ND-7513.2)
          ±3% for pressures over 70 psi  (NE-7S12.2)
          (NB-7513.1a)  (ND-7513.1a)
          (NC-7513.13)  (NE-7513.1a)
 (Continued)
                                    1 psi = 6.89 kPa
   289   290   291   292   293   294   295   296   297   298   299