182         Wastewater Solids Incineration Systems




                    cover fasteners should be reinstalled immediately following conveyor maintenance.
                    Gaskets should be inspected and replaced if deteriorated.
                        Mechanical systems may also be used to convey ash collected in waste heat
                    boilers, economizers, and baghouses.

                    3.2.1.2 Pneumatic Conveyance Systems
                    Pneumatic conveying devices are either pressure- or vacuum-driven. They consist of
                    airlock equipment—to prevent cross mixing of transport air and air within the incin-
                    erator on the lower hearths—and may include various combinations of ash coolers,
                    blowers or vacuum pumps, transporters, conveyance piping, ash bins, ash condi-
                    tioners, associated drive equipment, and dry dust removal equipment typically of the
                    baghouse type.
                        The dilute-phase pressure system (Figure 8.2) uses a positive-displacement or
                    centrifugal blower to move the air and ash mixture through piping to the storage
                    bins (Dynamic Air Inc, 2006a). Another type of dilute-phase pressure system

















                                                                                   Receiving Bin




                    Low Pressure
                    Blower
                                              Rotary
                                              Air Lock




                    FIGURE 8.2  A typical dilute-phase pressure system for ash handling (courtesy of
                    Dynamic Air, Inc.).