Page 349 - Wastewater Solids Incineration Systems
P. 349
310 Wastewater Solids Incineration Systems
FIGURE C.1 Westerly WWTP incinerator process flow stream (I.D. induced draft).
Figure C.1 shows the components of Westerly’s MHF system and Table C.2 pro-
vides all pertinent details for NEORSD.
3.1 Natural Gas
Natural gas used by the incineration process is metered.
64 792 MCF $6.18/MCF $400,415
3
MCF 1000 cu ft (28 m )
3.2 Electricity
Electricity used by the incinerator process is not separately metered. However, the
total horsepower of the incineration equipment is known as are the number of hours
per year in operation (see Table C.3).
275 total hp 0.746 kW/hp 6694 hours of operation $0.060/kWh $82,396